Specifications Section 2-1
Input response time setting Time constants can be set for inputs from Basic I/O Units.
The time constant can be increased to reduce the influence
of noise and chattering or it can be decreased to detect
shorter pulses on the inputs.
10-4-6 I/O Response
Time
Programming Manual:
6-6-1 I/O Response
Time Settings
Mode setting at power-up Possible (By default, the CPU Unit will start in RUN mode if a
Programming Console is not connected.)
7-1-2 PLC Setup Set-
tings
Programming Manual:
1-2 Operating Modes
and 1-2-3 Startup Mode
Flash memory (CJ1-H and
CJ1M CPU Units only)
The user program and parameter area data (e.g., PLC
Setup) are always backed up automatically in flash memory.
(automatic backup and restore.)
CPU Units with unit version 3.0 or later only:
When downloading projects from CX-Programmer Ver. 5.0 or
higher, symbol table files (including CX-Programmer symbol
names, I/O comments), comment files (CX-Programmer rung
comments, other comments), and program index files (CX-
Programmer section names, section comments, or program
comments) are stored in comment memory within the flash
memory.
---
Memory Card functions Automatically reading pro-
grams (autoboot) from the
Memory Card when the
power is turned ON.
Possible 3-2 File Memory
Programming Manual:
SECTION 5 File Mem-
ory Functions, 5-1-3
Files, and 5-2-2 CMND
Instruction
Program replacement during
PLC operation
Possible Programming Manual:
5-2-3 Using Instruction
in User Program
Format in which data is
stored in Memory Card
User program: Program file
format
PLC Setup and other param-
eters: Data file format
I/O memory: Data file format
(binary format), text format,
or CSV format
Programming Manual:
5-1 File Memory
Functions for which Memory
Card read/write is supported
User program instructions,
Programming Devices
(including CX-Programmer
and Programming Con-
soles), Host Link computers,
AR Area control bits, easy
backup operation
Programming Manual:
5-2 File Memory Oper-
ations
Filing Memory Card data and the EM (Extended Data Memory)
Area can be handled as files.
Programming Manual:
SECTION 5 File Mem-
ory Functions
Debugging Control set/reset, differential monitoring, data tracing (sched-
uled, each cycle, or when instruction is executed), instruction
error tracing, storing location generating error when a pro-
gram error occurs.
Programming Manual:
7-2 Trial Operation and
Debugging
Online editing User programs can be overwritten in program-block units
when the CPU Unit is in MONITOR or PROGRAM mode.
This function is not available for block programming areas.
With the CX-Programmer, more than one program block can
be edited at the same time.
Programming Manual:
1-2 Operating Modes
and 7-2-3 Online Edit-
ing
Program protection Overwrite protection: Set using DIP switch.
Copy protection: Password set using CX-Programmer or Pro-
gramming Consoles.
Programming Manual:
6-4-6 Program Protec-
tion
Item Specifications Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ1G/H-CPU series and is the answer not in the manual?

Omron CJ1G/H-CPU series Specifications

General IconGeneral
BrandOmron
ModelCJ1G/H-CPU series
CategoryController
LanguageEnglish

Related product manuals