7 Wiring
7 - 14
NX-series EtherNet/IP Coupler Unit User’s Manual (W536)
Precautions for Correct Use
Use cables with suitable wire sizes for the carrying current. There are also restrictions on the
current due to the ambient temperature. Refer to the manuals for the cables and use the
cables correctly for the operating environment.
Double-check all switches and other settings and double-check all wiring to make sure that
they are correct before turning ON the power supply.
Use the correct wiring parts and tools when you wire the system.
For twisted wires, strip the sheath and twist the conductor portion. Do not unravel or bend the
conductor portion of twisted wires or solid wires.
Additional Information
If more than 2 A will flow on the wires, use plated wires or use ferrules.
This section describes how to connect and remove wires.
Terminal Block Parts and Names
Required Tools
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
Connecting/Removing Wires
Unravel wires Bend wires
NG NG
Terminal hole
Release hole
2.5 mm
0.4 mm
Front view
8 to 12°
Side view
2.5-mm dia.

Table of Contents

Other manuals for Omron CJ2-CPU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CJ2-CPU and is the answer not in the manual?

Omron CJ2-CPU Specifications

General IconGeneral
BrandOmron
ModelCJ2-CPU
CategoryController
LanguageEnglish

Related product manuals