305
Pulse Outputs Section 5-3
Settings for PLS2(887) to Return to Start (D10 to D17)
Number of Repeats of Fixed-distance Positioning Operation (D20)
Setting details Address Data
Acceleration rate: 300 Hz/4 ms D10 #012C
Deceleration rate: 200 Hz/4 ms D11 #00C8
Target frequency: 50,000 Hz D12 #C350
D13 #0000
Number of output pulses: 10,000 × 15 pulses D14 #49F0
D15 #0002
Starting frequency: 100 Hz D16 #0000
D17 #0000
Setting details Address Data
Number of repeats of fixed-distance positioning operation
(number of PCBs in stocker)
D20 #0015