436
Analog I/O Units Section 7-4
Writing D/A Conversion
Data
Note Words (n+1, n+2) can be used for either the set data or the analog output
conversion value.
Note Words (n+1 to n+4) can be used for either the set data or the analog output
conversion value.
MOV(021)
Ladder program
CPU Unit CP1W-MAD42
(See note.)
Writes the conversion
values.
Word (n+2)
“n” is the last output word allocated to the CPU
Unit or previous Expansion Unit or Expansion I/O
Unit.
Analog devices
Adjustment equipment
Servo Controller
Variable speed device
Recorder
Other
Word (n+1)
Analog output 1
conversion value
Analog output 2
conversion value
MOV(021)
Ladder program
CPU Unit CP1W-MAD44
(See note.)
Analog output 1
conversion value
Analog output 2
conversion value
Analog output 3
conversion value
Analog output 4
conversion value
“n” is the last output word allocated to the CPU
Unit or previous Expansion Unit or Expansion I/O
Unit.
Analog devices
Adjustment equipment
Servo Controller
Variable speed device
Recorder
Other
Word (n+4)
Word (n+3)
Word (n+2)
Word (n+1)
Writes the conversion
values.

Table of Contents