EasyManua.ls Logo

Omron CP1H-X40D - Page 665

Omron CP1H-X40D
810 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
631
Standard Models Appendix A
CJ-series Special I/O Units
Temperature Sensor
Units
CP1W-TS004 Thermocouple inputs K or J, 12 inputs ---
CompoBus/S I/O Link
Unit
CP1W-SRT21 As a CompoBus/S slave, 8 inputs and 8 outputs are allocated.
Name and appearance Model Specifications Remarks
Analog Input Units CJ1W-AD081-V1 8 analog inputs 0 to 5 V, 1 to 5 V, 0 to 10 V,
10 to +10 V, 4 to 20 mA
Resolution: 1/8000
Resolution can
be set to 1/4000.
CJ1W-AD041-V1 4 analog inputs
Analog Output Units CJ1W-DA08V 8 analog outputs 0 to 5 V, 1 to 5 V, 0 to 10 V,
10 to +10 V
Resolution: 1/8000
Resolution can
be set to 1/4000.
CJ1W-DA08C 8 analog outputs 4 to 20 mA
Resolution: 1/8000
CJ1W-DA041 4 analog outputs 0 to 5 V, 1 to 5 V, 0 to 10 V,
10 to +10 V
Resolution: 1/8000
CJ1W-DA021 2 analog outputs
Analog I/O Unit CJ1W-MAD42 4 analog inputs and 2 analog outputs:
0 to 5 V, 1 to 5 V, 0 to 10 V, 10 to +10 V, 4 to 20 mA
Resolution: 1/4000
Resolution can
be set to 1/8000.
Process I/O
Units
Tempera-
ture Sen-
sor Units
CJ1W-PTS51 Thermocouple inputs R, S, K, J, T, L, or B; 2 inputs ---
CJ1W-PTS52 Platinum resistance thermometer inputs Pt100 or
JPt100, 4 inputs
CJ1W-PTS15 Thermocouple inputs B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII, or DC voltage (
±100 mV); 2 inputs
CJ1W-PTS16 Platinum resistance thermometer inputs Pt100 or
JPt100, JPt50, or Ni508.4; 2 inputs
Isolated-
type DC
Input Unit
CJ1W-PDC15 DC voltage:
0 to 125 V, 125 to +125 V, 0 to 5 V, 1 to 5 V,
5 to 5 V, 1 to 5 V, 0 to 10 V, 10 to +10 V,
or user-set range between 10 to +10 V
DC current: 0 to 20 mA or 4 to 20 mA
2 inputs
Name and appearance Model Specifications Remarks

Table of Contents