757
PLC Setup Appendix G
Origin Return Settings
Pulse Output 2 Settings
Base Settings
Name Default Settings When setting is read
by CPU Unit
Internal
address
Bits Settings
1 Speed 0 pps
(disabled)
1 pps At start of operation 289 and
288
00 to 15 0000 0001
hex
: :
100,000 pps (maxi-
mum for X/XA CPU
Unit)
1,000,000 pps
(maximum for Y
CPU Unit)
0001 86A0
hex
000F 4240
hex
2 Acceleration Ratio 0 (disabled) 1 (pulses/4 ms) At start of operation 290 00 to 15 0001Hex
: :
65535
(pulses/4 ms)
FFFF hex
3 Deceleration Ratio 0 (disabled) 1 (pulses/4 ms) At start of operation 291 00 to 15 0001 hex
: :
65535
(pulses/4 ms)
FFFF hex
Name Default Settings When setting is read
by CPU Unit
Internal
address
Bits Settings
1 Undefined Origin (oper-
ation for limit signal turn-
ing ON)
Hold Hold At start of operation 392 12 to
15
0 hex
Undefined 1 hex
2 Limited Input Signal
Operation
Search Only Search Only When power is turned
ON
380 04 to
07
0 hex
Always 1 hex
3 Limit Input Signal NC NC At start of operation 392 00 to
03
0 hex
NO 1 hex
4 Search/Return Initial
Speed
0 pps 0 pps At start of operation 383 and
382
00 to
15
0000 0000
hex
: :
30,000 pps 0000 7530
hex
5 Speed Curve Trapezium Trapezium When power is turned
ON
380 12 to
15
0 hex
S-shaped 1 hex

Table of Contents