62
Specifications Section 2-2
Note (1) The fuse cannot be replaced by the user.
(2) Also do not exceed 0.9 A for the total of CIO 100.00 to CIO 100.03, which
are different common.
(3) If the ambient temperature is maintained below 50°C, up to 0.9 A/com-
mon can be used.
!Caution Do not connect a load to an output terminal or apply a voltage in excess of the
maximum switching capacity.
Fuse 1 fuse/common (See note 1.)
Circuit configuration • Normal outputs CIO 100.00 to CIO 100.07
(Sinking Outputs)
• Normal outputs CIO 100.00 to CIO 100.07
(Sourcing Outputs)
• Normal outputs CIO 101.00, CIO 101.01 and
CIO 101.02 to CIO 101.07
(Sinking Outputs)
• Normal outputs CIO 101.00, CIO 101.01 and
CIO 101.02 to CIO 101.07
(Sourcing Outputs)
Item Specification
CIO 100.00 to CIO 100.07 CIO 101.00 and
CIO 101.01
CIO 101.02 to
CIO 101.07
OUT
OUT
COM (−)
L
L
Internal
circuits
Internal
circuits
24 VDC/
4.5 to
30 VDC
OUT
OUT
COM (+)
L
L
Internal
circuits
Internal
circuits
24 VDC/
4.5 to
30 VDC
OUT
OUT
COM (−)
L
L
Internal
circuits
24 VDC/4.5
to 30 VDC
OUT
OUT
COM (+)
L
L
Internal
circuits
24 VDC/4.5
to 30 VDC
0.9
0.6
0
5550
0
Common terminal
current (A)
Ambient temperature (°C)