219
Troubleshooting Procedures Section 8-4
Opening Problems
Closing Problems Refer to General Problems on page 218.
Y
Y
N
N
N
Y
Y
N
Opening Problems occurred.
Are you attempting
an active open?
Is the passive open
not finishing?
Use an active open at the
remote node.
Is the response
code in the results storage
area a value other
than 0049?
Read socket status using
the FINS command READ
SOCKET STATUS.
Does the port
number being used exist
at the local node?
Make sure that the same port number is not being used
simultaneously by more than one process, including FTP services.
Sockets can remain in ESTABLISHED or some later status even if
closed; be sure to close ports from both sides of the connection.
A socket can remain open in TIME WAIT status for up to one minute
on the side that closes the socket first; we recommend that the
active-side port number be set to 0 and that you close the socket
from the active side. If you are using the Socket Service Request
Switches, check the response code to see if it is 0049 Hex.
Return to General
Problems.

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals