EasyManua.ls Logo

Omron D6T Series - I2 C Communication Control and Registers; StartStop Conditions and Write Operations; Register Map and IIR Filter

Omron D6T Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D6T MEMS Thermal Sensors User’s Manual (A284) 12
Before performing the processing illustrated in Fig. 16, perform the following processing for
D6T-8L-09 models at least 20 msec after power is supplied to the module. This processing should
only be performed when power is first turned on.
Fig. 17. Signal Terminal Flow (D6T-8L-09)
SCL
S
W Command[7:0]( 0x02) Command[7:0]( 0x00)
SDA
Slave address[6:0] ( 0x0A)
Command[7:0]( 0x01) Command[7:0]( 0xEE)
P
S P
S P
S P
S P
S
W Command[7:0]( 0x02)
Slave address[6:0] ( 0x0A)
Sr
Command[7:0]( 0x00) Command[7:0]( 0x00)
P
Slave address[6:0] ( 0x0A)
S Sr P
S Sr P
Command[7:0]
(0x00)
Command[7:0]
(0x07)
Command[7:0]
(0xE9)
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x05)
Slave address[6:0]
(0x0A) + R
Command[7:0]
(0x90)
Command[7:0]
(0x3A)
R
Command[7:0]
(0x97)
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x03)
Command[7:0]
(0x00)
Command[7:0]
(0x03)
Command[7:0]
(0x8B)
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x05)
Command[7:0]
(0x90)
Command[7:0]
(0x3A)
Command[7:0]
(0xB8)
750msec w ait
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x03)
Command[7:0]
(0x00)
Command[7:0]
(0x07)
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x02)
Command[7:0]
(0x00)
Command[7:0]
(0x00)
Slave address[6:0]
(0x0A) + W
Command[7:0]
(0x03)
Slave address[6:0]
(0x0A) + R
ACK
ACK
ACK
ACK
ACK
ACK
ACK
NA CK
ACK
ACK

Related product manuals