Controlling Operation and Outputting Data with EtherNet/IP Communications
116
FQ2-S/CH User’s Manual
for Communications Settings
Execution of Control Commands for Continuous Measurements with the Control Command Execution Bit
(EXE) Signal
Overall judgement (OR)
There is no signal to acquire measurement
results during continuous measurements.
Command code
Command
parameters
Command code
Response code
Response data
(1) (2)
(4)
(5)(6)(3) (7)
Control
Command
Execution Bit
(EXE) signal
Command
Execution Active
(BUSY) signal
Control
Command
Completed
(FLG) signal
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Continuous measure-
ments executed.
(1) Set the Start Continuous Measurements command code and the command parameters from the PLC while the BUSY
signal is OFF.
(2)
The Controller turns ON the Control Command Execution Bit (EXE) signal. The execution command is sent to the Vision
Sensor.
(3)
When the Vision Sensor receives the execution command, the Command Execution Active (BUSY) signal turns ON, the
Trigger Input Ready (READY) signal turns OFF, and the command is executed. Continuous measurements start at this time.
(4)
The command code, response code, and response data are set when the Vision Sensor completes execution of the
command.
(5)
The Control Command Completed (FLG) signal turns ON.
(6)
When the PLC detects that the Control Command Completed (FLG) signal is ON, it turns OFF the Control Command
Execution Bit (EXE) signal.
(7)
When the Vision Sensor detects that the Control Command Execution Bit (EXE) signal is OFF, it automatically turns OFF
the Control Command Completed (FLG) signal. The BUSY signal remains ON until continuous measurements are
completed.
(8)
During continuous measurements, an OR of the measurement results is output each time a measurement is completed.
Command
Area
Response
Area
Trigger Input
Ready (READY)
signal
FQ2-S_CH_comm.book 116 ペー 01年626 木日 前1時4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S Series and is the answer not in the manual?

Omron FQ2-S Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S Series
CategorySecurity Camera
LanguageEnglish

Related product manuals