Command Control
250
FQ2-S/CH User’s Manual
for Communications Settings
Save Scene Data
This command saves scene data to the SD card inserted in the Touch Finder as a file.
The destination for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Vision Sensor)
*1 Saved as a file named Scene_***.scn. (***: Specified file number)
Response (Vision Sensor to PLC)
First word of com-
mand area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0000 0000 Command code
+3 0000 0000 0111 0000
+4 0000 0000 0000 0000 Number of the scene to be saved.
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000 • EtherNet/IP,
PROFINET
File number to load
(0 to 999)*1
• PLC link
File name to load
64 characters max.
The file name exten-
sion (.scn) can be
omitted.
+7 0000 0000 0000 0000
+8 0000 0000 0000 0000
---
: 0000 0000 0000 0000
+37 0000 0000 0000 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0001 0000 0000 0000 Command code
Response target command codes
+3 0000 0000 0111 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
FQ2-S_CH_comm.book 250 ページ 2014年6月26日 木曜日 午前11時47分