EasyManuals Logo

Omron FQ2-S Series User Manual

Omron FQ2-S Series
444 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #254 background imageLoading...
Page #254 background image
Command Control
252
FQ2-S/CH User’s Manual
for Communications Settings
Save System Data
Saves system data as a file to the SD card inserted in the Touch Finder.
The destination for system data is the following fixed directory on the SD card.
\Sensor name\SYD
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Vision Sensor)
*1 Saved as a file named SensorSys_***.syd. (***: Specified file number)
Response (Vision Sensor to PLC)
First word of com-
mand area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0011 0000 0000 0000 Command code
+3 0000 0000 0111 0000
+4 0000 0000 0000 0000 EtherNet/IP,
PROFINET
File number to load
(0 to 999)*1
PLC link
File name to load
64 characters max.
The file name exten-
sion (.syd) can be
omitted.
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000
---
: ::::
+35 0000 0000 0000 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0011 0000 0000 0000 Command code
Response target command codes
+3 0000 0000 0111 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
FQ2-S_CH_comm.book 252 ペー 01年626 木日 前1時4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S Series and is the answer not in the manual?

Omron FQ2-S Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S Series
CategorySecurity Camera
LanguageEnglish

Related product manuals