Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
FQ2-S/CH User’s Manual
for Communications Settings
55
2
Controlling Operation and Outputting Data with a Par-
allel Connection
It may happen that the PLC is unable to recognize BUSY signal ON because the sample time is slow or otherwise. In
this event, have W0.00 turn OFF at a suitable time.
Resetting the Sensor
Sensor reset is explained below.
Wiring
• This command is only valid in Expanded Mode.
• This function can only be used in Run mode.
Color Signal State Description
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
Section 2 Installation
and Connections
in Vision Sensor
FQ2-S/CH Series
User's Manual
(Cat. No. Z337)
Gray IN0 OFF Command parameters for Sensor reset
Green IN1 ON
Red IN2 OFF
White IN3 ON
Purple IN4 OFF
Yellow IN5 ON Command input for Sensor reset
Orange OUT1 (BUSY) -- Busy (default)
1 IN0, IN2 and IN4 are turned OFF, IN1
and IN3 are turned ON.
2 IN5 is turned OFF > ON with the
BUSY signal OFF. The BUSY signal
does not turn ON while the restart
command is being received.
3 When the initialization process starts,
the BUSY signal turns ON.
For the initialization process, refer to
the following:
Operation with Default Configu-
ration: p.34
Note
IN0 to IN4 signals
IN5 ON after at least 5 ms
ON at least 1 ms
IN5 signal
OFF
ON