- 33 -
• Mechanical life expectancy at 20°C100,000 operations
• Electrical life expectancy at 20°C
50,000 operations min. for a resistive load of 15 A at 250 VAC
50,000 operations min.
for an inductive load (cosf = 0.7) of 10 A at 250 VAC
50,000 operations min. for a motor load of 1 HP at 250 VAC
50,000 operations min. for a lamp load of 100 W at 100 VAC
10,000 operations min. for a lamp load of 300 W at 100 VAC
The higher the ambient temperature is, the shorter the Time Switch's
life expectancy will be.
Note 1: The total error including the repeat accuracy, setting error,variation due to voltage
change, and variation due to temperature change is ±0.01%±0.05s maximum.
Note 2: These figures are accumulated times.
10 to 55Hz,0. 5mm double
amplitude
Malfunction
durability
Mechanical
durability
Installation
environment
Over-voltage category II,
pollution degree 2
(as per IEC61010-1)
Minimum setting
interval
Monthly difference 15s (25°C)
Cyclic error
±0.01% ±50ms max.
Total error (Note1)
100m/s
2
Malfunction
durability
Mechanical
durability
ON/OFF operation:24
(12 sets of ON and OFF
operations)
pulse-output operation:24
Operations
Pulse width
–25 to +65°C
(Avoid freezing or condensation)
Ambient Storage
temparature
Ambient operating
temparature
5 years min.
10 years min
(Power-interruption rate
of 50%) Note2
MAX. 2,000 m
Altitude
10 to 55Hz,0. 75mm double
amplitude
Vibration
Inductive
Resistive
Configuration
Circuit
Number of circuits
Contact output(SPST-NO)
AC250V15A
Setting
Separated from power circuit
(no-voltage)
AC250V10A(cosφ=0.7)
–10 to +55°C
(Avoid freezing or condensation)
1(independent)
1min
24VDC (H5F-B-90)
100 to 240VAC 50/60Hz(other)
Supply voltage
85 to 110% of rated voltage
Operating voltage range
Can be set to 1to 59s in units of
1 second and to 1 to 60min in
units of 1 minute.
Approx.0.5W(H5F-B-90)
Approx.2.4VA(other)
Power consumption
300m/s
2
Shock
35 to 85 %Ambient humidity
UL508(Listing)
CSA C22.2 No.14(cULus)
EN61010-1(IEC61010-1)
EN61326
VDE0106/part100
Standards
Memory protection
4.Output(Built-inRelay)LifeExpectancy
5.RatingsandPerformanceCharacteristics
Load
Capacity