Note
F3 is displayed only when " totl" is selected in F2 (input selection).
• Alarm ( indicator) will be displayed when either the total time (F3) or the
total count (F4) reaches the set alarm value.
If an alarm value for the total time is set to 0, the alarm indicator does not appear.
• To leave initial setting mode, press for 3 s or more.
If is pressed again before confirming the setting, the setting is cancelled.
- 50 -
Weekly
2 chnls
Yearly
2 chnls
Yearly
4 chnls
The alarm value can be set for the total time. ( 6-1)
Setting
The setting is made in F3 (total time alarm) of initial setting mode.
The color indicates flashing.
Press for 3 s or more in program
setting mode to enter initial setting mode.
Give short presses on and
move to the F3 display.
Press to confirm the setting.
(After a one second pause, the screen returns to the initial display of F3.)
6-6-3. F3: Total Time Alarm
Setting range
0.0 to 99990.0 h
Time is set in 10 hour unit.
The default is 0.0h (The alarm indicator output is off).
TIME ADJ
TIME ADJ
TIME ADJ
TIME ADJ
WRITE
Set the Mode Switch to RUN.
Alarm value setting display appears
automatically in 2 s after entering F3.
Press or to set an alarm value.
decrements the value of the Key that was last pressed.)
: increments in 1,000 hour unit.
: increments in 10 hour unit.
m
h
h
m
(Pressing HOLIDAY/
SELECT PRGM/or