99
Appendix B
List of Settings
Menu Parameter Setting range Unit Set value
sUset
sU.hh HH set value
19999 to 99999 ---
Setting values menu
sU. h H set value
19999 to 99999 ---
sU. l L set value
19999 to 99999 ---
sU.ll LL set value
19999 to 99999 ---
scale
inp.2 Input value 2
19999 to 99999 ---
Scaling menu
dsp.2 Display value 2
19999 to 99999 ---
inp.1 Input value 1
19999 to 99999 ---
dsp.1 Display value 1
19999 to 99999 ---
decĆp Decimal point position %%%%%/%.%%%%/%%.%%%/%%%.%%/%%%%.%
setup
Setup menu
inĆt Input range DC voltage input: a Ud to e Ud
DC current input: a ad to d ad
AC voltage input: a Ua to d Ua
AC current input: a aa to d aa
---
fre Power supply frequency
50/60 Hz
uĆno Communications unit no.
00 to 99 ---
bps Baud rate
1200/2400/4800/9600/19200/
38400
bps
len Word length
7/8 bit
sbit Stop bits
1/2 bit
prty Parity bits
None/Even/Odd ---
opt
Option menu
aUg Average processing
No average processing
Movement average processing:
2, 4, 8, 16, or 32 times
Simple average processing:
2, 4, 8, 16, or 32 times
---
stine Startup compensation time
0.0 to 99.9 s
his Hysteresis
1 to 9999 ---
cĆout Comparative output pattern
Standard output, zone output, or
level output
---
sleety H linear output range
19999 to 99999 ---
sleety L linear output range
19999 to 99999 ---
rĆl Remote/local programming
Remote or local programming ---