EasyManua.ls Logo

Omron K3NX - Comparative Output Pattern (C Out)

Omron K3NX
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
Comparative Output Pattern
The pattern of HH, H, L, LL, and PASS comparative outputs is set in the option
menu.
Setting Default
nomal: Standard output
=one: Zone output
leUel: Level output
nomal
Standard Output
H or HH Comparative Output:
Turns ON when the measured value is larger than the H or HH setting value.
PASS Output:
Turns ON when LL, L, H, and HH comparative outputs are all OFF.
L or LL Comparative Output:
Turns ON when the measured value is smaller than the L or LL setting value.
HH setting value
H setting value
L setting value
LL setting value
Measured value
HH comparative output
H comparative output
PASS
L comparative output
LL comparative output
cĆout
FUNCTION
SETTING
REFERENCE
Setting Mode
Section 3-2
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Omron K3NX

Related product manuals