EasyManua.ls Logo

Omron OMNUC R88D-WT15HF

Omron OMNUC R88D-WT15HF
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-105
maximum torque decreases. When the normal temperature of 20°C and –10°C are compared, the
momentary maximum torque increases by approximately 4%. Conversely, when the magnet warms
up to 80°C from the normal temperature of 20°C, the momentary maximum torque decreases by
approximately 8%.
Generally, in a mechanical system, when the temperature drops the friction torque increases and the
load torque becomes larger. For that reason, overloading may occur at low temperatures. In particu-
lar, in systems which use deceleration devices, the load torque at low temperatures may be nearly
twice the load torque at normal temperatures. Check with a current monitor to see whether overload-
ing is occurring at low temperatures, and how much the load torque is. Likewise, check to see wheth-
er there abnormal Servomotor overheating or alarms are occurring at high temperatures.
An increase in load friction torque visibly increases load inertia. Therefore, even if the Servo Driver
parameters are adjusted at a normal temperature, there may not be optimal operation at low temper-
atures. Check to see whether there is optimal operation at low temperatures too.