30
SS2 series
G5 series
Remarks
Parameter
No.
[hex]
Parameter name
Default
setting
[dec]
Parameter
No.
[dec]
Parameter name
Default
setting
[dec]
Pn09
Warning Output
Selection
2
Pn411
Output Signal
Selection 2
00020202
hex
Select a function to set to the Warning Output
(WARN) output signal (CN1-12, 13 pins) of the
SS2 series.
The default setting of the SS2 series is 2:
Output for regeneration, overload, or fan
rotation speed alarm warning.
For the G5 series, use the general-purpose
output 2 for setting. The default setting of
Output Signal Selection 2 (Pn411) is
00020202 hex: Servo Ready Completed
Output (READY).
* If you set the 00090909 hex: Warning Output
1 (WARN), it will function the same as the
Warning Output (WARN) of the SS2.
Pn0A to
Pn0F
Not used.
-
-
-
-
-