31
9.2. Parameters Related to Gain
Set the proportional gain of position control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 s
-1
and
0.1 s
-1
.
Set the proportional gain of speed control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 Hz and
0.1 Hz.
Speed Loop
Integration Time
Constant
Speed Loop Integral
Time Constant
Set the integration time constant of speed
control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 ms and
0.1 ms.
Speed Feedback
Filter Time Constant
Speed Feedback
Filter Time Constant
Set the filter time constant in the speed detection
section.
● In both the SS2 and the G5 series, the default
setting is 0 (high responsiveness).
● In both the SS2 and the G5 series, increasing
the set value can suppress vibration but will
reduce responsiveness.
Torque Command
Filter Time Constant
Torque Command
Filter Time Constant
Set the torque command filter time constant of
torque control.
● The default setting differs between SS2 and
G5 series.
Speed Feed-forward
Amount
Set the feed-forward amount to be transmitted
from position control to speed control.
● In both the SS2 and the G5 series, the default
setting is 30%.
Feed-forward
Command Filter
Speed Feed-forward
Command Filter
Set the filter time constant in the feed-forward
section to be transmitted from position control to
speed control.
● The default setting differs between SS2 and
G5 series.
Set the proportional gain of position control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 s
-1
and
0.1 s
-1
.
Set the proportional gain of speed control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 Hz and
0.1 Hz.
Speed Loop
Integration Time
Constant 2
Speed Loop Integral
Time Constant 2
Set the integration time constant of speed
control.
● The default setting differs between SS2 and
G5 series.
● In setting, pay attention to the units, 1 ms and
0.1 ms.
Speed Feedback
Filter Time Constant
2
Speed Feedback
Filter Time Constant
2
Set the filter time constant in the speed detection
section.
● In both the SS2 and the G5 series, the default
setting is 0 (high responsiveness).
Torque Command
Filter Time Constant
2
Torque Command
Filter Time Constant
2
Set the torque command filter time constant of
torque control.
● The default setting differs between SS2 and
G5 series.
*1. For the numerical notation sv/SV, sv represents the setting for less than 1 kW drives of 100 V or 200 V type, and SV represents the
setting for other drives.