Notch 1 Frequency
Setting
Set the frequency of the 1st resonance
suppression notch filter.
● For the default setting of the SS2 series, the
notch function is disabled at 1,500 Hz.
● For the default setting of the G5 series, the
notch function is disabled at 5,000 Hz.
Set the width of the 1st resonance suppression
notch filter.
● In both the SS2 and the G5 series, the default
setting is 2.
● In both the SS2 and the G5 series, increasing
the set value will obtain a larger width.
* For the G5 series, the notch filter depth can
be set to Notch 1 Depth Setting (Pn203).
Set the ratio of load inertia to the motor rotor
inertia in units of %.
● For the SS2 series, it is automatically set when
you execute normal mode auto tuning. Or, it is
automatically updated when you enable
Realtime Autotuning Mode Selection
(Pn21).
● For the G5 series, it is automatically updated
when you enable Realtime Autotuning Mode
Selection (Pn002).
Realtime Autotuning
Mode Selection
Realtime Autotuning
Mode Selection
Set the functional operation that estimates the
load condition in real time and corrects the
control constant.
● The default setting of the SS2 series is 0:
Disabled.
● The default setting of the G5 series is 1: This
mode focuses on stability.
* In replacement, set it to 0: Disabled like the
SS2 series.
Realtime Autotuning
Machine Rigidity
Selection
Realtime Autotuning
Machine Rigidity
Setting
Set the rigidity of equipment for real-time auto
tuning.
● The default setting differs between SS2 and
G5 series. Adjust the setting according to the
rigidity of equipment.
Autotuning
Operation Setting
Set the operation pattern for normal mode auto
tuning.
● The G5 series does not have the related
parameter.
* For the G5 series, execute the auto tuning
with the operation pattern set, from CX-Drive
(computer tool).
Set the allowable operating range for the position
command input range. Going beyond the range
causes an Overrun Limit Error (Alarm No. 34) to
be detected.
● In both the SS2 and the G5 series, the default
setting is 1.0 rotation.
Damping control is a function that suppresses
vibration at the load end.
Set the damping frequency for the damping filter.
● In both the SS2 and the G5 series, the default
setting is 0.0 Hz and the damping filter is
disabled.
* Setting 0.0 to 0.9 Hz disables the damping
filter.
*1. For the numerical notation sv/SV, sv represents the setting for less than 1 kW drives of 100 V or 200 V type, and SV represents the
setting for other drives.