9. Detailed Comparison of Parameters
9.1. Function Selection Parameters
SS2 series
G5 series
Remarks
Parameter
No.
[hex]
Parameter name
Default
setting
[dec]
Parameter
No.
[dec]
Parameter name
Default
setting
[dec]
Pn00
Unit No. Setting
1
Pn531
Axis Number
1
Set the Unit No.
For the SS2 series, set the Unit No. to be
displayed on the Parameter Unit.
For the G5 series, it is an axis number setting
for USB communications.
Normally, do not change the set value.
* The G5 series does not have an operator unit.
Pn01
Default Display
1
Pn528
Default Display
1
Set the first data to be displayed on the
7-segment LED display after the power supply is
turned ON.
In both the SS2 and the G5 series, the default
setting is 1: Servomotor rotation speed.
Pn02
Control Mode
Selection
2
Pn001
Control Mode
Selection
0
Set the control mode to use.
The default setting of the SS2 series is 2:
Advanced Position Control.
The default setting of the G5 series is 0:
Position control (pulse train command), which
is a function equivalent to or higher than that of
the SS2 series.
* To use the internally set speed control in the
G5 series, set 1: Speed control (analog
command) to Control Mode Selection
(Pn001), and set 3: No. 1 Internally Set
Speed to No. 8 Internally Set Speed (Pn304
to Pn311) to Command Speed Selection
(Pn300).
Pn300
Command Speed
Selection
0
Pn03
Not used.
-
-
-
-
-
Pn04
Drive Prohibit Input
Selection
1
Pn504
Drive Prohibition
Input Selection
1
Set whether to enable or disable the drive
prohibition function.
In both the SS2 and the G5 series, the default
setting is 1: Disabled.
Pn05
Not used.
-
-
-
-
-
Pn06
Zero Speed
Designation/Torque
Limit Switch
1
Pn402
Input Signal
Selection 3
0091910A
hex
Select a function to set to the Gain Switch Input
(GSEL) input signal (CN1-5 pin) of the SS2
series.
The default setting of the SS2 series is 1: For
position control: Gain Switch Input (GSEL), For
speed control: Zero Speed Designation Input
(VZERO).
* When you set 2: Torque Limit Switch Input
(TLSEL), it will always operate as the Torque
Limit Switch Input (TLSEL).
For the G5 series, use the general-purpose
inputs 3 and 4 for setting.
The default setting of Input Signal Selection
3 (Pn402) is 0091910A hex: For position
control: Damping Filter Switching 1
(DFSEL1), For speed control or torque
control: Zero Speed Designation (VZERO).
The default setting of Input Signal Selection
4 (Pn403) is 00060606 hex: For position
control, speed control, or torque control: Gain
Switch Input (GSEL).
* If you set 00090909 hex: Torque Limit Switch
Input (TLSEL) to the general-purpose input 3
or 4, it will always operate as the Torque
Limit Switch Input (TLSEL).
Pn403
Input Signal
Selection 4
00060606
hex
Pn07
Not used.
-
-
-
-
-
Pn08
Not used.
-
-
-
-
-