Set the vibration suppression effect of the
damping filter.
● In both the SS2 and the G5 series, the default
setting is 0.0 Hz.
● In both the SS2 and the G5 series, increasing
the value will hasten the operation of vibration
suppression. Decrease the value if torque
saturation occurs to prevent vibration
suppression.
Adaptive Filter Table
Number Display
Notch 3 Frequency
Setting
This is a monitor that checks the operating status
of adaptive filters.
● For the SS2 series, you can check the
operating frequencies of adaptive filters.
● For the G5 series, the operating status of
adaptive filters is updated automatically to the
parameters of Notch 3/4 Frequency Setting
(Pn207/Pn210). For the default setting, the
notch function is disabled at 5,000 Hz.
Notch 4 Frequency
Setting
Gain Switching Input
Operating Mode
Selection
Gain Switching Input
Operating Mode
Selection
Set the function of gain switching input (GSEL).
● The default setting of the SS2 series is 1: The
gain will be switched between gain 1 in (Pn10
to Pn14) and gain 2 (Pn18 to Pn1C).
● The default setting of the G5 series is 1: Gain 1
(Pn100 to Pn104)/gain 2 (Pn105 to Pn109)
switching available.
* When 0: Gain 1 (PI/P switching enabled) is
set, speed control can be switched to
proportional (P) control to reduce the gain.
Switching Mode in
Position Control
Select a condition for switching between Gain 1
and Gain 2.
● The default setting of the SS2 series is 0:
Always gain 1 (Pn10 to Pn14).
● For the G5 series, position control and speed
control can be configured differently.
• The default setting of Switching Mode in
Position Control (Pn115) is 0: Always Gain
1 (Pn100 to Pn104).
• The default setting of Switching Mode in
Speed Control (Pn120) is 0: Always the
Gain 1 (Pn100 to Pn104).
Switching Mode in
Speed Control
Gain Switching
Delay Time in
Position Control
Set the delay time for returning from Gain 2 to
Gain 1.
● The default setting of the SS2 series is 30 x
166 us (4,980 us).
● For the G5 series, position control and speed
control can be configured differently.
• The default setting of Gain Switching Delay
Time in Position Control (Pn116) is 5.0 ms.
• The default setting of Gain Switching Delay
Time in Speed Control (Pn121) is 0.0 ms.
Gain Switching
Delay Time in
Speed Control