34
SS2 series
G5 series
Remarks
Parameter
No.
[hex]
Parameter name
Default
setting
[dec]
Parameter
No.
[dec]
Parameter name
Default
setting
[dec]
Pn33
Gain Switch Level
Setting
600
Pn117
Gain Switching
Level in Position
Control
50
Set the judgment level for switching between
Gain 1 and Gain 2.
The default setting of the SS2 series is 600.
* The unit varies with the set value of Gain
Switch Setting (Pn31).
For the G5 series, position control and speed
control can be configured differently.
The default setting of Gain Switching Level
in Position Control (Pn117) is 50.
* The unit varies with the set value of
Switching Mode in Position Control
(Pn115).
The default setting of Gain Switching Level
in Speed Control (Pn122) is 0.
* The unit varies with the set value of
Switching Mode in Speed Control
(Pn120).
Pn122
Gain Switching
Level in Speed
Control
0
Pn34
Gain Switch
Hysteresis Setting
50
Pn118
Gain Switching
Hysteresis in
Position Control
33
Set a hysteresis to the judgment level for
switching between Gain 1 and Gain 2.
The default setting of the SS2 series is 50.
* The unit varies with the set value of Gain
Switch Setting (Pn31).
For the G5 series, position control and speed
control can be configured differently.
The default setting of Gain Switching
Hysteresis in Position Control (Pn118) is
33.
* The unit varies with the set value of
Switching Mode in Position Control
(Pn115).
The default setting of Gain Switching
Hysteresis in Speed Control (Pn123) is 0.
* The unit varies with the set value of
Switching Mode in Speed Control
(Pn120).
Pn123
Gain Switching
Hysteresis in Speed
Control
0
Pn35
Position Loop Gain
Switching Time
20 x
166 us
Pn119
Position Gain
Switching Time
3.3
ms
In switching between gains, the phased switching
time can be set for position loop gain only.
The default setting of the SS2 series is 20 x
166 us (3,320 us).
The default setting of the G5 series is 3.3 ms.
Pn36 to
Pn3F
Not used.
-
-
-
-
-