Brake Timing When
Stopped
Brake Timing when
Stopped
Set the servo ON hold time, at servo OFF, after
the brake interlock output turned OFF.
● The default setting differs between SS2 and
G5 series.
Brake Timing during
Operation
Brake Timing During
Operation
Set the time spent waiting for the brake that
reduces rotation to be applied when the Servo
OFF is applied to the running motor.
● The default setting of the SS2 series is 50 x 2
ms (100 ms).
* For the SS2 series, when the speed reaches
30 r/min or less, the brake will be applied
even if the wait time set in Brake Timing
during Operation (Pn6B) has not elapsed.
● The default setting of the G5 series is 0 ms.
* For the G5 series, when the motor speed
reaches not more than the speed set in
Brake Release Speed Setting (Pn439), the
brake will be applied even if the wait time set
in Brake Timing During Operation (Pn438)
has not elapsed.
Brake Release
Speed Setting
Regeneration
Resistor Selection
Regeneration
Resistor Selection
Set the regeneration processing method.
● The default setting of the SS2 series is 0:
Built-in capacitor.
● The default setting of the G5 series is 3:
Built-in capacitor.
* The default setting of the Servo Drive with a
built-in regeneration resistor is 0: Built-in
regeneration resistor.
Overspeed
Detection Level
Setting
Overspeed
Detection Level
Setting
Set the detection level of an Overspeed error
(Alarm No. 26).
● In both the SS2 and the G5 series, the default
setting is 0 r/min.
* In both the SS2 and the G5 series, if you set
0 r/min, it will be detected when the motor
speed is 1.2 times as high as the maximum
one.
When Torque Limit Switch Input (TLSEL) is
enabled, set the No. 2 torque limit in units of %,
with the rated motor torque regarded as 100%.
● For the SS2 series, it will be enabled when you
set 2: Torque Limit Switch Input (TLSEL)
Enabled to Zero Speed Designation/Torque
Limit Switch (Pn06). No. 2 Torque Limit
(Pn71) is enabled for forward and reverse
operation when Torque Limit Switch Input
(TLSEL) is used.
● For the G5 series, it will be enabled when you
set 3: No. 1 Torque Limit (Pn013) / No. 2
Torque Limit (Pn522) Switching to Torque
Limit Selection (Pn521). No. 2 Torque Limit
(Pn522) is enabled for forward and reverse
operation when Torque Limit Switch Input
(TLSEL) is used.
No. 2 Deviation
Counter Overflow
Level
Error Counter
Overflow Level
When Torque Limit Switch Input (TLSEL) is
enabled, set the Error Counter Overflow Error
(Alarm No. 24) detection level limited by the No.
2 torque limit.
* The G5 series has no parameter of No. 2
Deviation Counter Overflow Level. Use
Error Counter Overflow Level (Pn014)
together with the No. 1 torque limit.
*2. For the numerical notation sv/SV, sv represents the setting for the following drives. SV represents the setting for other drives.
● 100 V type: 200 W or less ● 200 V type: 400 W or less, 7.5 kW, 15 kW ● 400 V type: 7.5 kW, 15 kW