5-10
5-2 Warning Function
5
Maintenance Operations
Warning appears when a target code set data meets the condition shown above in relation to the base code
data.
Parameters are rewritten into the data of the base code. (rewritten at start-up)
091/291 Frequency upper limit A061/A261 >
Free V/f frequency 7
b112
092/292 Frequency lower limit A062/A262 >
095/295
Output frequency F001, Multi-step speed reference 0 A020/
A220
*2
>
096 Multi-step speed reference 1 to 15 A021 to A035 >
110
Free V/f frequencies 1 to 6
b100, b102, b104, b106, b108, b110
>
Free V/f frequencies 2 to 6
b102, b104, b106, b108, b110
<
Free V/f frequency 1
b100
Free V/f frequency 1 b100 >
Free V/f frequency 2
b102
Free V/f frequencies 3 to 6 b104, b106, b108, b110 <
Free V/f frequencies 1, 2 b100, b102 >
Free V/f frequency 3
b104
Free V/f frequencies 4 to 6 b106, b108, b110 <
Free V/f frequencies 1 to 3 b100, b102, b104 >
Free V/f frequency 4
b106
Free V/f frequencies 5, 6 b108, b110 <
Free V/f frequencies 1 to 4 b100, b102, b104, b106 >
Free V/f frequency 5
b108
Free V/f frequency 6 b110 <
Free V/f frequencies 1 to 5
b100, b102, b104, b106, b108
>
Free V/f frequency 6
b110
120
Free electric thermal frequencies 2, 3 b017, b019 <
Free electric thermal
frequency 1
b015
Free electric thermal frequency 1 b015 >
Free electric thermal
frequency 2
b017
Free electric thermal frequency 3 b019 <
Free electric thermal frequencies 1 2 b015, b017 >
Free electric thermal
frequency 3
b019
Warning display Target code Condition Base code
*1. In this case, the base frequency is rewritten when correcting parameters. Change the data to a correct value
if a warning occurs. Otherwise, the motor may burn out depending on the value.
*2. Checks even if the frequency reference selection (A001) is set other than to the Digital Operator (02).
*3. The jump frequency is rewritten into the value of the subtraction of the jump width (lower limit) from the jump
frequency.