4-2 Function Mode
4
Functions
Reduced Voltage Startup Selection
•Slowly increases voltage during motor startup.
•To increase torque during startup, reduce the set value of reduced voltage startup selection b036.
Note that if the value is too small, the motor starts in full-voltage starting mode, possibly resulting
in an overcurrent trip.
Display Selection
•You can change the items to be displayed on the Digital Operator.
Parameter No. Function name Data Default setting Unit
b036
Reduced voltage startup
selection
00: Reduced voltage startup disabled
01 to 255:
01: Short (approx. 6 ms)
255: Long (approx. 1.53 s)
6
Related functions b082
FW
Output
frequency
Output
voltage
Starting frequency
b082
00 01 06
Parameter No. Function name Data Default setting Unit
b037 Display selection
00: Complete display
01: Individual display of functions
02: User setting
03: Data comparison display
04: Basic display
04
U001 to U012 User selection
_ _no: No allocation
no
d001 to P131: Select the code you want to
display. (Among all codes. Note that P100 to
P131 cannot be used.)