7-5
7-1 Standard Specification List
7
Specifications
* Complies with the test method specified in JIS C0040 (1999).
Note: Insulation distance complies with UL/CE standards.
Carrier frequency
modification range
0.5 to 15 kHz
Protective functions
Overcurrent protection, Overvoltage protection, Undervoltage protection, Electronic
thermal protection, Temperature error protection, Momentary power interruption/Power
interruption protection, Input phase loss protection, Braking resistor overload protection,
Ground-fault current detection at power-on, USP error, External trip, Emergency shutoff
trip, CT error, Communication error, Option error, etc.
Operating environment
Ambient/Storage
temperature/
Humidity
-10C to 50C/-20C to 65C/20% to 90% RH (with no condensation)
Vibration *
RX-A004 to A220
5.9 m/s
2
(0.6G), 10 to 55 Hz
RX-A300 to A550, B4750 to B413K
2.94 m/s
2
(0.3G), 10 to 55 Hz
Location At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Options
Feedback option Sensor vector control
Digital input option 4-digit BCD, 16-bit binary
Other options
Braking resistor, AC reactor, DC reactor, Digital Operator cables, Noise filter, Braking
unit, etc.
Item Specifications