3-28
3-7 Parameter List
3
Operation
External frequency adjustment
A101 OI start frequency
0.00 to 99.99
100.0 to 400.0
0.00 No Hz
4-14
A102 OI end frequency 0.00 No Hz
A103 OI start ratio 0. to OI end ratio 20. No %
A104 OI end ratio OI start ratio to 100. 100. No %
A105 OI start selection
00: Use OI start frequency [A101]
01: 0 Hz
00 No
A111 O2 start frequency -400. to -100.
-99.9 to 0.00 to 99.99
100.0 to 400.0
0.00 No Hz
4-15
A112 O2 end frequency 0.00 No Hz
External frequency adjustment
A113 O2 start ratio -100. to O2 end ratio -100. No %
A114 O2 end ratio O2 start ratio to 100. 100. No %
Acceleration/Deceleration
A131
Acceleration curve
parameter
01 (small curve) to 10 (large curve)
02 No
4-38
A132
Deceleration curve
parameter
02 No
Operation frequency
A141
Operation frequency
input A setting
00: Digital Operator (F001)
01: Digital Operator (FREQ adjuster)
(Enabled when 3G3AX-OP01 is used.)
02: Input O
03: Input OI
04: RS485 communication
05: Option 1
06: Option 2
07: Pulse train frequency
02 No
4-41
A142
Operation frequency
input B setting
03 No
A143 Operator selection
00: Addition (A + B)
01: Subtraction (A - B)
02: Multiplication (A × B)
00 No
A145
Frequency addition
amount
0.00 to 99.99
100.0 to 400.0
0.00 No Hz
4-41
A146
Frequency addition
direction
00: Add A145 value to output frequency
01: Subtract A145 value from output
frequency
00 No
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.