3-1SectionData Carrier Motion and Command Conditions
20
1, 2, 3...
1. Send a polling auto command to Unit 1 R/W Head 1.
2. The ID Controller Immediately receives the command and returns a
response indicating that it has received the command.
3. Send a polling auto command to Unit 2 R/W Head 2.
4. The ID Controller immediately receives the command and returns a
response indicating that it has received the command.
5. The
host computer can query the status of processing using subcommands
or suspend polling auto processing.
6. When
the DC is not close to the specified R/W Head, a “not close” response
is returned in response to a query subcommand.
7. When
a data carrier passes in front of Unit 1 R/W Head
1, write or read pro
-
cessing is performed.
8. Once processing is completed, the ID Controller sends a response to the
host computer indicating that the processing indicated by the query sub-
command has been completed.

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C