Page #62 background imageLoading...
Page #62 background image
4-3SectionBasic Operations
59
4-2-4 Reading Error Data
Operation
mode
Description Basic operation procedure Page
Error logging
function
selection
Selects ID
Controller error
logging function
ERR 1
2
3
4
Reads
error occurrence data
Reads error statistics
Clears stored error data
Clears error statistics
72
Read error data Up to 30 errors
occurring in the
RUN Mode are
stored, and new
occurrences are
displayed in the
order of
occurrence along
with head
numbers and error
codes.
1ERR ResetINC
DEC
(Cancel
operation)
Display messages using
73
Read error
statistics
Subtotals of errors
occurring in RUN
Mode are
displayed by type.
2ERR ResetINC
DEC
(Cancel
operation)
Display messages using
74
Clear stored
error data
Stored error data
is cleared.
ERR SET3
75
Clear error
statistics
Error statistics are
cleared, and the
data (year
, month,
day) for starting
collection of
statistics is
specified.
4ERR DATASET
Num. key Num. key
Num. key
SET
Clear statistics
(yr) (mo) (day)
76
4-3 Basic Operations
4-3-1 Changing Operation Mode
The following describes how to switch the ID Controller operation mode. By
pressing
the Left or Right Arrow Key when MONIT
OR is displayed, the English
or
Japanese display can be selected. The selected display
will be on hold until
the Left or Right Arrow Key is pressed again.
English characters or Japanese characters can be selected.
Monitor Mode The Monitor Unit key operations can only be used in the MONITOR Mode.
Communications to the host computer stop when the MONITOR Mode is
entered.
MONITOR
MONITOR
Relationship between Mode
Switch and Display

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals