4-6SectionReading Error Information (ERR)
75
3. When
the INC Key is pressed, the number of error occurrences for the first
error
code 10 is displayed. The maximum number of occurrences that can
be counted for each error code is 999.
4. While the error code is being displayed, use the horizontal cursor keys to
display
the error
messages. When a horizontal cursor key is pressed again,
the error code display is restored.
5. Press the INC Key to read the error occurrence conditions sequentially.
Press the DEC Key to perform the reverse operation.
6. After displaying occurrence conditions for all errors, press the INC Key to
display the MCBF. MCBF is obtained by dividing the total number of host
commands by the total number of occurrences of communications errors
(see note below).
Note This
includes all communications errors with the host computer
,
R/W
Head, DC, and other devices.
4-6-3 Clear Error Data
Error data is cleared from memory.
3
SET
ERROR14
CLEAR L?
a00d00
ERR
RESET
(2)
(1)
(3)
1, 2, 3...
1. When the ERR Key is pressed, the error menu is shown on the display.
2. Press the 3 Key.
3. When
the SET Key is pressed, the error
data is cleared, and address/data
display is restored.
Note To
cancel the error data clear command, press the SET Key before
pressing the RESET Key.