EasyManuals Logo

Omron V600 Series Operation Manual

Omron V600 Series
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Appendix CAuto Read/Auto Write
112
Application Example of Command
Item Application Description Note
Command
transmission by
timer
Transmits next auto command after
response is returned.
R/W
Head
When DC passes
through the
communications area of
R/W Head at fixed
intervals.
If a long time elapses
before next DC arrives.
Overlapping of the
same communication
with the same DC can
be avoided if wait time
during which DC leaves
the communication area
elapses after the end of
communication.
Keep transportation
speed constant.
Valid only for systems
where communication is
not made more than
once with same DC.
Make sure that another
DC does not pass
through the area.
Trigger Transmits next auto command when a
trigger is received after a response is
returned.
R/W
Head
Trigger
For example, auto
command is transmitted
after end of processing
for preceding process is
confirmed.
Trigger must be input
before the next DC
approaches.
Trigger processing is
necessary.
Make sure that the
trigger is accurately
input.

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C