3-4SectionCommand Types and Responses
40
Subcommand Format
P R C/E 1/2
Header
Polling
auto
read
R/W Head no.
Specifies cancel or inquiry of polling auto preprocessing
results
C: Processing result inquiry
E: Cancel
For 1 to 1 procedure
P R C/E 1/2
Header
@ Unit No. FCS
Polling
auto
read
R/W Head no.
Specifies cancel or inquiry of polling auto preprocessing
results
C: Processing result inquiry
E: Cancel
For 1 to N procedure
00
to 15
Subcommand Response Format
PR00XXX X
Header
Polling
auto
read
For 1 to 1 procedure
.......
Read
data (at normal end only)
End code (see page
48)
00:
At normal end
74: DC not close (after second pass)
75:
Polling auto processing canceled (before communica
-
tions processing with DC)
76:
Polling a to processing canceled (the DC approaches,
and processing is canceled during communications
processing with the DC and after completion of proces
-
sing)
Read data (at normal end only)
@ FCSUnit No.
Header
For 1 to N procedure
Polling
auto
read
PR00XXX X
.......
End code (see page
48)
00:
At normal end
74: DC not close (after second pass)
75:
Polling auto processing canceled (before communica
-
tions processing with DC)
76:
Polling a to processing canceled (the DC approaches,
and processing is canceled during communications
processing with the DC and after completion of proces
-
sing)
00 to 15