148
SECTION 5
V680 Commands
RFID System
User’s Manual
SECTION 5
Communications
Parameter data
(when there are changes)
Data No. (See note 2.) Settable values
“C” Specify 4 decimal digits. “0000” to “9999” (ms)
“0000”: Infinite, Default value: “0500” (ms)
“D” Specify 4 hexadecimal digits. “0001” to “0800” (bytes)
Default value: “0001” (bytes)
“E” “00”: No noise detection for communications history (default value)
Noise monitor function disabled.
“01”: Noise detection for communications history
Noise monitor function enabled.
“F” “00”: Two Output Mode
BUSY, ERROR, OUT1, and OUT2 (default value)
“01”: Four Output Mode
OUT1, OUT2, OUT3, and OUT4
“G” Specify 4 decimal digits. “0001” to “0100” (times)
Default value: “0010” (times)
“H” “00”: Write protection OFF
“01”: Write protection ON (default value)
Note 1: Parameters 1, 2, 9, and H are valid only when internal settings are enabled (i.e., when pin 1 on SW3 is ON).
Note 2: The data number of the parameter data is the number specified for the lower digit of the process code.
The settable values for the data number are the same as for the parameter specified by the lower digit of the process
code.
Parameter data Attached only when parameter data is being obtained.
Response
S
00
22
2
* CR
1 to 4
P
0
1
0
1
Command
code
Terminator
End code
Resend flag
Fixed
value
×
Parameter data
×
×
×