151
RFID System
User’s Manual
SECTION 5
V680 Commands
SECTION 5
Communications
OPERATION MODE CHANGE (MO)
The OPERATION MODE CHANGE command is used to change the mode of the ID Controller.
1:1 Protocol
Before changing the operation mode to Self Execution Mode, use the OPERATION CONDITION SET command to set
the operation conditions. If the OPERATION MODE CHANGE command is executed with the process designation set to
“S” when the operation conditions have not been set, an execution status error (end code 15) will occur.
p. 153
If the OPERATION MODE CHANGE command is executed in Host Communications Monitor Mode with the process
designation set to “S,” an execution status error (end code 15) will occur. To change from Host Communications Monitor
Mode to Self Execution Mode, first change to Command Execution Mode.
1:N Protocol
Before changing the operation mode to Self Execution Mode, use the OPERATION CONDITION SET command to set
the operation conditions. If the OPERATION MODE CHANGE command is executed with the process designation set to
“S” when the operation conditions have not been set, an execution status error (end code 15) will occur.
p. 153
If the OPERATION MODE CHANGE command is executed in Host Communications Monitor Mode with the process
designation set to “S,” an execution status error (end code 15) will occur. To change from Host Communications Monitor
Mode to Self Execution Mode, first change to Command Execution Mode.
Process designation Specifies the operation mode of the ID Controller.
S: Self Execution Mode
C: Command Execution Mode
P: Host Communications Monitor Mode
Execution designation Always “0”.
Process designation Specifies the operation mode of the ID Controller.
S: Self Execution Mode
C: Command Execution Mode
P: Host Communications Monitor Mode
Execution designation Always “0”.
Command
MO
21
2
* CR
1
Command
code
Terminator
×
Process
desig-
nation
Execution
designation
×
Response
MO
00
22
2
* CR
0
1
0
1
Command
code
Terminator
End code
Resend flag
Fixed
value
Command
MO
×
21
2
* CR
1
@
2
0
11
2
FCS
Command
code
Terminator
Controller No.
×
Process
desig-
nation
Execution
designation
×
××
×

Other manuals for Omron V680-CA5D01-V2