158
SECTION 5
V680 Commands
RFID System
User’s Manual
SECTION 5
Communications
5. Read the operation conditions.
Reading Operation Conditions
Command: SE10*[CR]
Response: SE00C1RDRAH100100010; C2XX; S101>=00000212340100; S201ER000000000100; S3XX; S4XX; U101AL; U2XX*[CR]
CH1 command
CH2 command
OUT1 output condition OUT2 output condition
OUT3 output condition
OUT4 output condition
CH1 output
setting
CH2 output