225
RFID System
User’s Manual
SECTION 5
V600 Commands
SECTION 5
Communications
1:N Protocol
Process code Always “00”.
OUT1/OUT2 controls 0: No operation
1: Turn ON
2: Turn OFF
End code Indicates the execution result for the command.
“00” indicates a normal end.
Refer to List of End Codes for information on other end codes.
p. 235
Input status The current input status (1st character: TRG1, 2nd character: TRG2)
0: OFF
1: ON
Output status The output status after processing (1st character: OUT1, 2nd character: OUT2)
0: OFF
1: ON
Command
CC
00
2
2
* CR
1
2
OUT1
control
1
OUT2
control
2
FCS
3
@
Command
code
Terminator
Controller No.
×
Process
code
×
×
×
×
×
Response
CC
00
2
2
* CR
2
2
Input
status
2
Output
status
@
3
2
FCS
Command
code
Terminator
End code
Controller No.
×
×
×
×
×
××
×