n084 Jump Frequency 2 0.00Hz
n085 Jump Frequency 3 0.00Hz
n086 Jump Frequency Range 0.00Hz
n087 Cumulative operation time
function selection
0
n088 Cumulative operation time 0H
n089 DC Injection Braking Current 50%
n090 DC Injection Braking Time at
Stop
0.5s
n091 DC Injection Braking Time at
Startup
0.0s
n092 Stall Prevention During
Deceleration
0
n093 Stall Prevention Level During
Acceleration
170%
n094 Stall Prevention Level During
Running
160%
n095 Frequency Detection Level 0.00Hz
n096 Overtorque Detection
Function Selection 1
0
n097 Overtorque/Undertorque Detec-
tion Function Selection 2
0
n098 Overtorque Detection Level 160%
n099 Overtorque Detection Time 0.1s
n100 Hold Output Frequency
Saving Selection
0
n101 Speed Search Deceleration
Time
2.0s
n102 Speed Search Operation
Level
150%
n103 Torque Compensation Gain 1.0
n104 Torque Compensation Time
Constant
0.3s
(Note4)
n105 Torque Compensation Iron
Loss
(Note3)
Parameter
No.
Description Factory
Setting
n106 Motor Rated Slip (Note3)
n107 Motor Line-to-neutral
Resistance
(Note3)
n108 Motor Leakage Inductance (Note3)
n109 Torque Compensation
Voltage Limiter
150%
n110 Motor No-load Current (Note3)
n111 Slip Compensation Gain 0.0s
(Note4)
n112 Slip Compensation Time
Constant
2.0s
(Note4)
n113 Slip Compensation During
Regenerative Operation
0
n114 SI-T/V7 BUS Detection Counter 2
n115 Stall Prevention Above Base
Speed During Run
0
n116 Acceleration/deceleration Time
during Stall Prevention
0
n117 Undertorque Detection
Function Selection 1
0
n118 Undertorque Detection Level 10%
n119 Undertorque Detection Time 0.1s
n120 Frequency Reference 9 0.00Hz
n121 Frequency Reference 10 0.00Hz
n122 Frequency Reference 11 0.00Hz
n123 Frequency Reference 12 0.00Hz
n124 Frequency Reference 13 0.00Hz
n125 Frequency Reference 14 0.00Hz
n126 Frequency Reference 15 0.00Hz
n127 Frequency Reference 16 0.00Hz
n128 PID Control Selection 0
Parameter
No.
Description Factory
Setting
I43-EN-01+V7+Quick_Guide.book Seite 16 Dienstag, 25. April 2006 8:56 08

Other manuals for Omron V7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V7 and is the answer not in the manual?

Omron V7 Specifications

General IconGeneral
SeriesV7
Cooling MethodForced air cooling
Power Rating0.4kW to 15kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Output Voltage3-phase 200 to 240 VAC, 3-phase 380 to 480 VAC

Related product manuals