EasyManua.ls Logo

Omron VS mini J7 - Page 164

Omron VS mini J7
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
150
List of Parameters Chapter 10
n39
(0127)
Multi-function
input 4 (Input
terminal S5)
2 Reverse/
Stop
Reverse rotation
command in 2-wire
sequence
(Reversed with the
terminal turned ON)
2 to 8,
10 to
22, 34,
35
16No 5-17
3 External
fault (NO)
ON: External fault
(FP_ detection: _ is a
terminal number)
4 External
fault (NC)
OFF: External fault
(EF_ detection: _ is a
terminal number)
5 Fault reset ON: Fault reset
(disabled while RUN
command is input)
6 Multi-step
speed
reference 1
Signals to select
freqency references 1
through 8.
Refer to 5-5-4 Setting
Frequency
References through
Key Sequences for
the relationship
between multi-step
speed references and
frequency references.
7 Multi-step
speed
reference 2
8 Multi-step
speed
reference 3
10 Inching
frequency
command
ON: Inching
frequency command
(taking precedence
over the multi-step
speed reference)
11 Accelera-
tion/Deceler-
lation time
changeover
ON: Acceleration time
2 and deceleration
time 2 are selected.
12 External
base block
command
(NO)
ON: Output shut off
(while motor coasting
to a stop and “bb”
flashing)
13 External
base block
bommand
(NC)
OFF: Output shut off
(with motor free
running and “bb”
flashing)
14 Search
command
(Searching
starts from
maximum
frequency)
ON: Speed search
(Searching starts from
n09)
15 Search
command
(Searching
starts from
preset
frequency)
ON: Speed search
16 Accelera-
tion/Deceler-
ation prohibit
command
ON: Acceleration/
Deceleration is on
hold (running at
parameter frequency)
17 Local or
remote
selection
ON: Local mode
(operated with the
Digital Operator)
Para-
meter No.
(Register
No. (Hex))
Name Description Setting
range
Unit of
setting
Default
setting
Changes
during
operation
Refer-
ence
page

Table of Contents

Related product manuals