74 Statistics
AS7200 User Manual - OPEX Corporation use only - not for distribution
The Jams section lists the reasons for the jams that occur.
Table 6: Reasons for jams
Duplicate Batch
Detected
A batch could not be started because a batch with the
same name already exists.
Too Many
Consecutive
Rejects
Results when the number of consecutive rejects is
greater than the machine parameter maximum
consecutive reject count.
Software
Problem
Detected
Results when the controller receives invalid information
from the host or there is an assert or exception within the
controller.
Vertical Turn
Sensor Missing
Results when the controller is expecting to see a piece
pass by the vertical turn sensor but it has not within the
time period that we are expecting it.
Stacker Entry
Sensor Missing
Results when the controller is expecting to see a piece
pass by the stacker entry sensor but it has not within the
time period that we are expecting it.
Bin 2 Gate
Sensor Missing
Results when the controller is expecting to see a piece
pass by the bin 2 gate sensor but it has not within the
time period that we are expecting it.
Bin 3 Gate
Sensor Missing
Results when the controller is expecting to see a piece
pass by the bin 3 gate sensor but it has not within the
time period that we are expecting it.
Bin 4 Gate
Sensor Missing
Results when the controller is expecting to see a piece
pass by the bin 4 gate sensor but it has not within the
time period that we are expecting it.
Bin 5 Gate
Sensor Missing
Results when the controller is expecting to see a piece
pass by the bin 5 gate sensor but it has not within the
time period that we are expecting it.
Feed Entry
Multifeed Sensor
Blocked
The Feed Entry MultiFeed Sensor is blocked.