Loading...
9.5-18VDC
+
–
N.C.
COM
N.O.
N.C.
COM
N.O.
SPSP
T.O.(N.C.)
AUX
(N.C.) (N.C.)
TAMPER
(N.C.) (N.C.)
TAMPER
INPUT
TROUBLE
OUTPUT
ALARM
POWER
+
–
SPSP
AUX
INPUT ALARM
POWER
9.5-18VDC
*1:
TAMPER terminals to be connected to a 24 hour supervisory loop.
TAMPER OUTPUT
(N.C.) *1
AUX INPUT
(N.C.)
TROUBLE OUTPUT
(N.C.)
SPARE (Non short)
ALARM OUTPUT (N.O.)
ALARM OUTPUT (COM)
ALARM OUTPUT (N.C.)
POWER INPUT (-) (9.5 - 18VDC)
POWER INPUT (+) (9.5 - 18VDC)
HX-40AM
HX-40DAM
HX-40
2-4
WIRING
Power wires should not exceed the following lengths.
WIRE GAUGE
HX-40 HX-40AM HX-40DAM
12 V 14 V 12 V 14 V 12 V 14 V
AWG22 (0.33 mm
2
)
160 m
(520')
360 m
(1,180')
140 m
(460')
310 m
(1,020')
120 m
(390')
250 m
(820')
AWG20 (0.52 mm
2
)
260 m
(850')
560 m
(1,840')
230 m
(750')
490 m
(1,610')
180 m
(590')
390 m
(1,280')
AWG18 (0.83 mm
2
)
410 m
(1,350')
900 m
(2,950')
360 m
(1,180')
780 m
(2,560')
290 m
(950')
630 m
(2,070')
- 10 -