Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount
Scanner
Page 33
6. Options for Code 39
Computer
Command
Function
/Description
Bar Code
Command
(Z7)
START/END
Programming Menu
-[8-
7C
Enable 1 character (3 characters
including start/stop characters)
-8D-
7D
Disable 1 character
-8E-
%
C0
Disable check digit calculation
-D1-
%
C1
Enable check digit calculation
-D2-
C2
Transmit check digit
-D3-
%
C3
Do not transmit check digit
-D!-
D0
Do not transmit start/stop
characters (*……*)
-E1-
D1
Transmit start/stop characters
(*……*)
-E2-
%
43 Data digits are available: 0 to 9, A to Z (caps only) plus . - $ / + % and space.
If a check digit is present, it will appear as part of the data.
If the scanner is programmed to calculate the check digit, and the bar code is not printed with a
check digit, the bar code will not read.
Another option available for Code 39 is to enable the reading of a single character bar code. See the
section on Fixing the Digit for this option.