Manual No. 25-ULPNR101-03; Feb, 2003 LPN5627 / LPR5627 Laser Fixed Mount
Scanner
Page 40
12. Setting Prefixes (Identifying the Symbology) (continued)
Computer
Command
Function
/Description
Bar Code
Command
(Z7)
START/END
Programming Menu
-[8-
M8
Code 93
-N9-
M9
Code 128
-N:-
D8
IATA
-E9-
N0
MSI/Plessey
-O1-
Z4
Display Prefix/Suffix
value and length (expressed in
hexidecimal format)
-[5-
13. Setting Suffixes (Identifying the Symbology)
Computer
Command
Function
/Description
Bar Code
Command
(Z7)
START/END
Programming Menu
-[8-
1Z
Clear all Suffixes
-2[-
N6
UPC-A
-O7-
O0
UPC-A +2 or +5
-P1-
N7
UPC-E
-O8-
O1
UPC-E +2 or +5
-P2-
N8
EAN-13
-O9-