EDFA optical amplifier – user manual
51
Report the automatic laser shutdown function for stage 2 is disable.
AM{sp}[O,C,P,G]{cr} Change the operation mode.
Change the operation mode of the EDFA between the 4 modes : ACC, APC, AGC, OFF.
Example usage:
AM{sp}O{cr}
Change the operation of the EDFA module to off mode. In OFF mode, the
laser diode driving current are set to 0 mA, alarms are disabled, and TEC are
enabled.
Reply is:
AM{sp}O{cr}
AM{sp}C{cr}
Change the operation of the EDFA module to current constant mode (ACC
mode).
Reply is:
AM{sp}C{cr}
AM{sp}P{cr}
Change the operation of the EDFA module to output power constant mode
(APC mode).
Reply is:
AM{sp}P{cr}
AM{sp}G{cr}
Change the operation of the EDFA module to constant gain mode (AGC
mode).
Reply is:
AM{sp}G{cr}