Route the HD/SSD power cable through the opening in the chassis divider (3).
Connect three of the power supply cables to the motherboard (4).
Connect the power supply cable to the hard disk backplane.
Install the air duct. See
“How to Install the Air Duct”on page 53.
Prepare the server for operation. See
“How to Prepare for Operation”on page 26.
Removing and Installing a Hard Drive Filler and Hard
Drive Assembly (CRU)
This section contains the following topics:
■
“How to Remove a Hard Drive Filler” on page 48
■
“How to Install a Hard Drive Filler” on page 49
■
“How To Remove a Removable Hard Drive Assembly” on page 50
■
“How to Install a Removable Hard Drive Assembly” on page 51
▼
How to Remove a Hard Drive Filler
Caution – Thermal over-temperature potential. Do not operate the server without all drive slots
populated with either a drive of a ller.
If your server contains a ller panel, remove the ller panel before installing a hard drive.
4
5
6
7
8
Removing and Installing a Hard Drive Filler and Hard Drive Assembly (CRU)
Sun Fire X2270 M2 Server Service Manual • January, 2012, –1248