Position the blower module so that it ts over the guideposts and the duct opening ts into the
cutouts in the chassis divider.
Gently push the blower module down while directing the connector cable through the cutout in
the chassis divider, until the blower is seated on the guideposts.
Note – Ensure that the connector cable has been directed through the connector opening in the
chassis divider and not through the blower exhaust opening.
Connect the blower power connector to the blower power connector on the motherboard.
Prepare the server for operation. See
“How to Prepare for Operation”on page 26.
■
“How to Remove a Blower Module” on page 54
■
“Replacing a Blower Module (CRU)” on page 54
Replacing the Hard Drive Backplane Assembly (FRU)
Note – The hard drive backplane assembly is a eld-replaceable unit. It must be replaced by a
certied Oracle Service Technician.
This section contains the following topics:
■
“How to Remove the Hard Drive Backplane” on page 57
■
“How to Install the Hard Drive Backplane” on page 58
1
2
3
4
See Also
Replacing the Hard Drive Backplane Assembly (FRU)
Sun Fire X2270 M2 Server Service Manual • January, 2012, –1256