Install the air duct. See “How to Install the Air Duct”on page 53.
Prepare the server for operation. See
“How to Prepare for Operation”on page 26.
“How to Remove the SATA Cable Harness” on page 62
Replacing the Front I/O Cable (CRU)
This section contains the following topics:
■
“How to Remove the Front I/O Cable” on page 63
■
“How to Install the Front I/O Cable” on page 63
▼
How to Remove the Front I/O Cable
See:
“Sun Fire X2270 M2 Server Internal Cabling” on page 61.
Prepare the server for service. See
“How to Prepare for Service”on page 21.
Remove the air duct. See
“How to Remove the Air Duct”on page 53.
Disconnect the I/O cable from the I/O board.
Disconnect the two I/O cable connections from the motherboard.
Carefully pull the I/O cable through the cutout in the chassis divider and lift it from the chassis.
“How to Install the Front I/O Cable” on page 63
▼
How to Install the Front I/O Cable
See:
■
“Sun Fire X2270 M2 Server Internal Cabling” on page 61
■
“How to Remove the Front I/O Cable” on page 63
Connect the two I/O cable connections to the motherboard.
Carefully route the I/O cable through the cutout in the chassis divider and over the top of the HD
partition.