28
Setup Manual - Butler XT2
Butler XT2 configuration
dialog in network status
window cannot be opened
Butler XT2 is bound in
Programmer and “Enable
Driver” is set.
Remove Butler XT2 in
Device Manager or disable
driver is Device Manager’s
configuration dialog.
Realtime Triggers do not
work at the selected time/
date
Butler XT2 Base Time/
Date correct? Triggers
transferred to Butler XT2
Butler XT2 Base Time and
Date is configurable in
the Device Setup via the
network overview window.
Run a quick update in the
Programmer.
Show behaves differently if
uploaded to the Butler XT2
Only supported stan-
dalone Triggers used?
For detailed information
check “System Manual
LAS” chapter “16.7 Pos-
sible Trigger”.
Hardware
Problem Check Cause
EP in display Push “System” button on
Butler XT2.
The Butler XT2 has an
e:bus output detection.
This reacts for example
in case of a short circuits,
or “HotPlug” of e:bus
devices.
New e:bus device not
found
Export new showfile with
no e:bus devices.
Butler XT2 supports as
a maximum eight e:bus
devices.
CRD in display (in stan-
dalone mode)
New SD card? If using a new SD card
please upload a showfile..
CRD in display (in stan-
dalone mode)
No assigned cuelist? Butler XT2 can only play
exported cuelists.
Glass Touchscreen without
function or reboots perma-
nently or screen flickers.
Cable to long, wrong
diameter?
View e:bus cable lengths
and diameters in specifica-
tion.