N086~MUST~EQUAL~N106~FOR~THIS~CONFIGURATION
Maximum Engine Speed using Switch Inputs (N086) must be equal to PTO Mode
Minimum Engine Speed (N106) when Mobile Pedal-Only configuration is selected
N086~MUST~BE~GTE~N106
Maximum Engine Speed using Switch Inputs (N086) must be greater than or equal
to PTO Mode Minimum Engine Speed (N106)
N101~MUST~BE~ENABLED
Disable PTO Mode w/ Brake Depressed (N101) must be enabled if Mobile PTO w/
Pedal and Switch Controls are selected, and PTO Mode Vehicle Speed Limit (N080)
is greater than 3 MPH
N102~INVALID~FOR~THIS~CONFIGURATION
Signal Source for Remote Main Switch (N102) can only be configured for CAN (1)
for Remote PTO control configurations
N106~MUST~BE~LT~800~IF~N079~AND~N089~ARE~DISABLED
PTO Mode Minimum Engine Speed (N106) cannot be greater than 800 RPM if
Require Parking Brake for PTO Mode (N079) and Neutral Required for PTO Mode
(N089) are disabled
N110~MUST~EQ~NONE~(1)~FOR~THIS~CONFIGURATION
Engine Speed Capture or Engine Speed Preset w/ Set Switch (N110) must be set to
NONE for mobile PTO applications
TSC1~NOT~ALLOWED
TSC1 Engine Speed Control is not allowed, unless Remote PTO w/o Throttle Pedal
control type is selected

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paccar MX Series and is the answer not in the manual?

Paccar MX Series Specifications

General IconGeneral
Engine TypeDiesel
ConfigurationInline 6-cylinder
Displacement12.9 liters
Torque Range1850 lb-ft
Emission StandardGHG17
Bore5.12 inches (130 mm)
AspirationTurbocharged
Fuel SystemCommon Rail